PHYSICAL DATA
Temperature Range: 0 to 1000¢µ (-18 to 538¡É).
Outputs: User configurable 4-20 mA or thermocouple output (J, K, E, N, R, S, T).
Alarm Outputs: IMS1:5 VDC; IMS2: 10 Amp SPDT relays.
Emissivity: 0.1 to 1.09 digitally adjustable increments of .01.
Accuracy: ¡¾1% of reading or ¡¾2¢µ(¡¾1¡É) whichever is greater.
Repeatability: ¡¾0.5% of reading or ¡¾2¢µ(¡¾1¡É) whichever is greater.
Temperature Resolution:0.5¢µ (0.3¡É).
Response Time: 700 mS (95%).
Distance-to-Target Size Ratio: IMS1: 35:1; IMS2: 3:0.1.
Spectral Response: 8 to 14 §.
Power Supply 110/220 VAC.
Ambient Operating Temp: Sensing head: 32 to 150¢µ (0 to 65¡É); Monitor: 32 to 120¢µ (0 to 50¡É).
Storage Temperature: -22 to 150¢µ (-30 to 65¡É).
Display: 4-digit, 7-segment LED display
Housing: Sensor: NEMA 4 (IP65); Meter front panel: NEMA 12.
Weight: Sensor: 0.7 lbs (320 g); Meter: 1 lb (454 g). |