PHYSICAL DATA Temperature Range: 32 to 662°F (0 to 350°C).
Thermocouple: 86 to 932°F (30 to 500°C) linear voltage. Emissivity:
0.95 fixed. Accuracy: ±2% of reading or ±6°F (±3°C) whichever is
greater for 32 to 240°F (0 to 115°C); ±5% of reading or ±10°F (±6°C) whichever
is greater for 24 to 440°F (116 to 225°C); >±5% of reading for 44 to 662°F
(226 to 350°C). Repeatability: ±1% of reading or ±2°F (±1°C) whichever
is greater. Response Time: 350 ms. Temperature Resolution:
1°F (< 0.5°C). Distance-to-Target Size Ratio: 4:1. Spectral
Response:7 to 18 microns. Power Supply: 12-24 VDC (Less than or
equal to 2.5% ripple) @ 20mA. Ambient Operating Temp: 32 to 160°F (0
to 70°C). Storage Temperature: -22 to 185°F (-30 to
85°C). Housing: NEMA 4 (IP65), stainless steel. Cable
Length: 3 ft (0.9 m). Weight: 4.5 oz (130 g).
STOCKED MODELS in bold
Model Number |
Output |
IL10 IL30 |
J Thermocouple 0-5V |
-µµ¸é
|