PHYSICAL DATA Service: Liquid, Gas, or
Vapor Output: 4-20 mA DC, limited to 30 mA DC (636), 1-5 VDC
(636LP) Null: 4.0 mA ±2% span (636), 1 VDC ±1% span
(636-LP) Span: 16.0 mA ±1% span (636), 4 VDC ±1% span
(636LP) Power Supply: 12 to 30 VDC (636), 8 to 14 VDC (636LP), reverse
polarity protection Loop Resistance: 900 ¥Ø max. @
30V Temperature Limits: Electronics (Ambient): -40 to 140°F (-40 to
60°C) Process Interface: -40 to 212°F (-40 to
100°C) Overrange: 300% upper range limit Accuracy: ±0.30% of
calibrated span Stability: ±0.5% of upper range limit for six
months Thermal Effect: (includes zero and span). Between -20° and
180°F (-29° and 82°C). ±2.0% per 50°F (28°C) Wetted Parts: 316 L
SS Fill Fluid: DC 200 Silicone (Standard) Process
Connection: ½" NPT(F) Electrical Connection: ¾"
NPT(F) Weight: 0.83 lbs. (374 g) Cable Length: 24" (61 cm),
22 AWG
STOCKED MODELS in bold
Model Number |
Operating Range, PSI |
Operating Range, Bar |
4-20 mA OUT |
1-5 VDC OUT |
636-0 636-1 636-2 636-3 |
636-0-LP 636-1-LP 636-2-LP 636-3-LP |
0-15 0-30 0-100 0-300 |
0-1 0-2 0-7 0-20 | |